Dänische Vorschrift 2011 und 2015 (Englisch)

From Wiki-WindPRO
Revision as of 09:59, 21 June 2024 by Robin (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Zur deutschen Hauptseite | Alle deutschsprachigen Seiten

December 2011 introduced new noise codes in Denmark[1].

The 2011 code was in 2015 replaced by a revised code[2] with the only change being that temporary refugee shelters would be permitted within the noise boundary of the turbines.

A full overview of the implications of the code can be found in [3].

The code is to a large extent based on the 2007 codes with three significant novelties:

a. Low frequency calculation
b. Documentation requirement
c. 15 dB limitation

The propagation model is using a separate damping for offshore wind turbines.

For the actual procedure of calculating the normal noise and the noise limits please refer to the 2007 codes as documented in previous manual versions as these are unchanged. The available inputs are accordingly:

Wind speed: The noise impact must be calculated for two wind speeds: 6 and 8 m/s at 10 m height.

Frequency: Octave band distribution is required for the calculation.

Ground attenuation and Directivity correction: The user must select whether the calculation is for on- or offshore turbines. This affects the ground attenuation. Note the correction is added to, not reduced from the calculated noise. The higher figure offshore thereby gives higher calculation values offshore. The selection of offshore or onshore turbines is done under Offshore / water areas.

Pure tones: Pure tone penalty is added to total noise from all turbines at receptors where tonality is measured. The penalty is 5 dB. If any turbine used in the calculation has a checked tonality box for one of the relevant wind speeds, the tonality penalty is triggered for all calculated receptors.

Height of immission point above ground level: The receptor height is default set to 1.5m.

Deviation from official noise demand: This field is open to the user.

Noise receptors: The critical limits at noise receptor are defined below.


Low frequency calculation

The low frequency calculation is concerned with the frequencies from 10 to 160 Hz. For this purpose a new tab is introduced in the turbine catalogue from version 2.8 containing low frequency figures. Data are entered in the tab as 1/3 octave frequencies in the same way as other data in the catalogue. Please note that if data are entered as 1/3 octave for normal noise, the form is automatically filled for low frequency noise as well. However in older versions of windPRO the two lowest frequencies were not available so opening a turbine with 1/3 octave data from before 2.8 will leave the two lowest frequencies empty.

It is strongly recommended to enter the full spectrum as third octave values and let WindPRO derive the low frequency values from this. This ensures consistency between low frequency and broadband calculations.



Noise limits

The noise limit for low frequency noise is uniformly 20 dB at any receptor (indoor) at 6 and 8 m/s at 10 m height. In the noise receptor properties, select Danish 2019 Low frequency, which is valid for the 2011/2015/2019 codes. The form allows for two kinds of receptors, Regular dwellings and Cottage zones, however with the 2011/2015 codes all receptors are treated as standard dwellings.


Noise calculation

When starting the calculation select as calculation type Danish 2011 and 2015 Low Frequency. The only available choice is whether to calculate for offshore turbines. If that hatch is checked, click the button Edit water areas to select an area object defining the sea. It is so that the low frequency calculation uses special dampings at sea and land and in the 200 m coastal zone makes a transition between the two calculation types. Note that the transition calculation is only for low frequency noise, not normal noise.


Pure tones

Tonality penalty according to the Danish rules is decided at the individual receptor. If a noise measurement at the receptor shows tonality enough to trigger a tonality penalty a new calculation must be done for this receptor adding 5 dB to the cumulative noise from turbines. This tonality is controlled from the NSA object where the 5 dB penalty can be set for the receptor (Pure tone penalty). Tonality setting on the wind turbines are ignored and receptors without the tonality penalty will ignore the tonality.


Documentation requirements

Due to increased documentation requirements previous practice of using the total noise figure and assuming a generic octave band distribution for existing turbines is now invalid. The noise figures used for existing turbines must be backed up by noise measurement reports for the turbine type and be available at least as 1/1 octave band distributions. If these are not available generic values provided by Miljøstyrelsen must be applied. For this reason when doing a noise calculation with Danish 2011 and 2015 or Danish Low frequency windPRO will for turbine types <=2MW use data from the generic tables from Miljøstyrelsen (Danish EPA) if data at least at 1/1 octave band level has not been selected for the turbine.

For turbine types >2MW the dB(A) value of the turbine is ignored and a generic value and distribution based on generator size is calculated. This is intended to reflect generic turbine types with unknown noise data. All other turbine types >2MW in Denmark MUST be calculated with turbine specific octave band distributions.

In the Decibel report a remark is added to the source noise summary if insufficient data are used or if generic data from the guideline is used.


Source Noise Project data

A specific catalogue of source noise data is provided for existing turbines in Denmark. The data are part of the Source Noise Project (Kildestøjsprojektet) and the database is documented by Grontmij in the document “Støjkatalog over ældre vindmøller i Danmark”, dated June 11, 2014; updated August 28, 2015.

The catalogue requires a special license from EMD. With this license noise records will appear in the wind turbine catalogue labeled KST. The records cannot be edited and are not visible for non-license holders. Each record holds the average 1/1 octave band distribution for the turbine type based on available measurements. In case of large scatter on the result an uncertainty is added to the frequency band.

The database is a realistic suggestion for the actual noise of old, existing turbines and has been been recognized by the Danish EPA as a valid alternative to the generic values of the guideline.


15 dB limitation

The 2011 Danish codes states that total noise at all receptors cannot exceed the noise limit. This means that noise contribution from existing turbines and new turbines must be combined and calculated for all receptors. As a practical limitation the guideline limits this by the 15 dB limitation. This means that existing turbines must be included when calculating noise for the neighbors to the new turbines if the contribution from existing turbines is higher than 15 dB below what they will get from the new turbines. It also means that noise must be calculated and comply with the present code at neighbors to existing projects if the contribution of noise from the new turbines is higher than 15 dB below what they get from existing turbines already. The practical aspects of this limitation is explained in “Experiences with the New Danish Rules for the Calculation of Low Frequency Noise from Wind Turbines”, Sorensen, 2012.


References:

  1. Danish Ministry of the Environment Miljøministeriet: Bekendtgørelse nr. 1284 af 15. december 2011, with guideline: Støj fra Vindmøller, Vejledning fra Miljøstyrelsen nr. 1, published 16 May 2012; http://www.mst.dk/Publikationer/Publikationer/2012/Maj/978-87-92903-08-2.htm
  2. Danish Ministry of the Environment Miljøministeriet: Bekendtgørelse nr 1736 af 21/12/2015
  3. Thomas Sorensen: Experiences with the New Danish Rules for the Calculation of Low Frequency Noise from Wind Turbines, 15th International Meeting on LowFrequency Noise and Vibration and its Control Stratford upon Avon UK 22nd –24th May 2012


Alle Module
Handbuch DECIBEL auf einer Seite ♦ Handbuch NORD2000 auf einer Seite
Diese Seite: Dänische Vorschrift 2011 und 2015 (Englisch)
DECIBEL DECIBEL-ÜberblickDECIBEL-BerechnungDECIBEL-Ergebnisse
NORD 2000 NORD2000-ÜberblickNORD2000-BerechnungNORD2000-ErgebnisseNORD2000-Referenzen
Datengrundlage Schall-ImmissionsorteWEA-SchalldatenauswahlBearbeiten von Schalldaten im WEA-KatalogSchallmatrix
Liste der Schallmodelle ISO 9613-2 AllgemeinISO 9613-2 Deutschland (Interimsverfahren)ISO 9613-2 DeutschlandISO 9613-2 FinnlandISO 9613-2 FrankreichISO 9613-2 PolenISO 9613-2 Vereinigtes KönigreichDänemark 2019 (Englisch) ♦ Dänemark 2019 Tieffrequent (Englisch) ♦ Finnland TieffrequentNiederlande 2011 (Englisch) ♦ Norwegen 2012 (Englisch) ♦ Schweden 2009 (Englisch) ♦ Veraltete Schallmodelle
Sonstiges SchallreflexionenInteraktive IsophonenMaximalpegel-KarteManuelle Tieffrequenz-BerechnungGenerisches OktavbandMeteorologische DämpfungTechnischer Anhang (Englisch)