Difference between revisions of "Writing multiple timeseries to meteo object from MCP2005"
Jump to navigation
Jump to search
(Created page with "Category:windPRO 3.2 Service Pack 1 Category:windPRO Known Issues-3.2 Category:windPRO Known Issues '''Status:''' Open - will be fixed in windPRO 3.2 Service Pack...") |
|||
(One intermediate revision by one other user not shown) | |||
Line 3: | Line 3: | ||
[[Category:windPRO Known Issues]] | [[Category:windPRO Known Issues]] | ||
− | '''Status:''' | + | '''Status:''' Fixed in windPRO 3.2 Service Pack 1 |
'''Fixed in build:''' 670 | '''Fixed in build:''' 670 | ||
Line 10: | Line 10: | ||
1) Two meteo objects have been created from MCP2005, A & B | 1) Two meteo objects have been created from MCP2005, A & B | ||
+ | |||
2) If you exit MCP2005, open and close Meteo Object A the data is saved/updated as expected. | 2) If you exit MCP2005, open and close Meteo Object A the data is saved/updated as expected. | ||
+ | |||
3) Due to an error, opening and closing Meteo Object B will replace the time series data of Meteo Object A. | 3) Due to an error, opening and closing Meteo Object B will replace the time series data of Meteo Object A. | ||
Latest revision as of 13:05, 19 June 2018
Status: Fixed in windPRO 3.2 Service Pack 1
Fixed in build: 670
Writing multiple time series to meteo objects from the same MCP2005-calculation can cause data loss if you subsequently open and close the meteo objects. Example:
1) Two meteo objects have been created from MCP2005, A & B
2) If you exit MCP2005, open and close Meteo Object A the data is saved/updated as expected.
3) Due to an error, opening and closing Meteo Object B will replace the time series data of Meteo Object A.
Note that this error does not apply to the new edition of MCP.
Workaround: Before closing the generated meteo objects with "OK" ensure that the "Object data placement" has been set to "Internal" in the Meteo Object Setup found on the Data-tab.