Difference between revisions of "Writing multiple timeseries to meteo object from MCP2005"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
[[Category:windPRO Known Issues]] | [[Category:windPRO Known Issues]] | ||
− | '''Status:''' | + | '''Status:''' Fixed in windPRO 3.2 Service Pack 1 |
'''Fixed in build:''' 670 | '''Fixed in build:''' 670 |
Latest revision as of 13:05, 19 June 2018
Status: Fixed in windPRO 3.2 Service Pack 1
Fixed in build: 670
Writing multiple time series to meteo objects from the same MCP2005-calculation can cause data loss if you subsequently open and close the meteo objects. Example:
1) Two meteo objects have been created from MCP2005, A & B
2) If you exit MCP2005, open and close Meteo Object A the data is saved/updated as expected.
3) Due to an error, opening and closing Meteo Object B will replace the time series data of Meteo Object A.
Note that this error does not apply to the new edition of MCP.
Workaround: Before closing the generated meteo objects with "OK" ensure that the "Object data placement" has been set to "Internal" in the Meteo Object Setup found on the Data-tab.