Category:WindPRO 4.0 Service Pack 2: Difference between revisions

From Wiki-WindPRO
Jump to navigation Jump to search
No edit summary
Line 14: Line 14:


==DECIBEL==
==DECIBEL==
*Fixed report issue for Finish Low Frequency calculation which could display too many frequencies. Recalculation required {{Templink40SP2|06_0490}}
*Fixed issue with conversion of noise data from 10m to HH for turbines with binned curtailments {{Templink40SP2|06_0479}}
*Fixed issue with conversion of noise data from 10m to HH for turbines with binned curtailments {{Templink40SP2|06_0479}}
*Fixed issue where a WTG with PowerMatrix could not be used in when using the setting "Wind speed at 95% of rated power" {{Templink40SP2|06_0486}}
*Fixed issue where a WTG with PowerMatrix could not be used in when using the setting "Wind speed at 95% of rated power" {{Templink40SP2|06_0486}}
*Fixed display issue in object form for noise results using pseudo wind speeds {{Templink40SP2|06_0487}}{{Templink40SP2|06_0488}}
*Fixed display issue in object form for noise results using pseudo wind speeds {{Templink40SP2|06_0487}}{{Templink40SP2|06_0488}}
*Fixed report issue for Finish Low Frequency calculation which could display too many frequencies. Recalculation required {{Templink40SP2|06_0490}}
*Fixed report issue for DECIBEL calculations combining "Highest noise value at receptor" with uncertainty {{Templink40SP2|06_0495}}
*Fixed report issue for DECIBEL calculations combining "Highest noise value at receptor" with uncertainty {{Templink40SP2|06_0495}}
*Fixed issue with warning about missing noise data appearing repeatedly for interactive noise line calculations {{Templink40SP2|06_0496}}
*Fixed issue with warning about missing noise data appearing repeatedly for interactive noise line calculations {{Templink40SP2|06_0496}}

Revision as of 13:36, 12 March 2024

March 2024, build 4.0.540

Below you will find a list of all issues fixed in Service Pack 2

This Service Pack contains corrections to bugs and comments reported by users. Thanks to all for submitting feedback.

See list of previous releases here: windPRO releases

The items below are ordered alphabetically by module, then by importance.

BASIS

DECIBEL

  • Fixed report issue for Finish Low Frequency calculation which could display too many frequencies. Recalculation required Go to TD in Story Manager
  • Fixed issue with conversion of noise data from 10m to HH for turbines with binned curtailments Go to TD in Story Manager
  • Fixed issue where a WTG with PowerMatrix could not be used in when using the setting "Wind speed at 95% of rated power" Go to TD in Story Manager
  • Fixed display issue in object form for noise results using pseudo wind speeds Go to TD in Story Manager Go to TD in Story Manager
  • Fixed report issue for DECIBEL calculations combining "Highest noise value at receptor" with uncertainty Go to TD in Story Manager
  • Fixed issue with warning about missing noise data appearing repeatedly for interactive noise line calculations Go to TD in Story Manager
  • Fixed issue with the reset of the "Use default value from calculation" and "Use default uncertainty margin from model" in the NSA object. Pure tone penalty setup deactivated in NSA, when calculating with German propagation model. Go to TD in Story Manager
  • Added a checkbox for deactivation of the additional result table in "DECIBEL, detailed results graphic" in the report properties Go to TD in Story Manager
  • Added message dialog if low frequency noise calculation has been configured to calculate "Distance to noise demand" and no turbines exceeded the threshold Go to TD in Story Manager
  • Increased the minimum height of the DECIBEL window Go to TD in Story Manager
  • Fixed window size of NSA setup for German translations Go to TD in Story Manager

LOSS & UNCERTAINTY

METEO

Fixed issue where entering a very large number (e.g. 999999) for "Days in window" would throw an exception Go to TD in Story Manager

MODEL

Slightly improved handling of Socket Error exception. Final solution has not been found.

NORD2000

Go to TD in Story Manager

ONLINE DATA

PARK

  • Fixed issue with incorrect GROSS AEP in the report of time based PARK calculation, when more curtailments per time stamp was active. Go to TD in Story Manager
  • Fixed issue where entering the same value in "From" and "To" in the Displacement Height Calculator would produce 0-values Go to TD in Story Manager
  • Fixed issue where running a timevarying PARK calculation on a virtual machine with 2 cores would thrown an error message Go to TD in Story Manager
  • Fixed issue in IEC power curve correction where rated power would not be detected for certain power curves with high-wind ramp-down Go to TD in Story Manager
  • Added ability to see user label when selecting WTGs to include in report/ result to file Go to TD in Story Manager

PERFORMANCE CHECK

RESOURCE

SCRIPTING

SHADOW

SITE COMPLIANCE

T-RIX tool

TR10

Fixed issue with manually entered scaling factors Go to TD in Story Manager

This category currently contains no pages or media.