*Clarified help text in turbine catalogue concerning blade width {{Templink35SP2|01_2982}}
*Clarified help text in turbine catalogue concerning blade width. {{Templink35SP2|01_2982}}
*Fixed issue where copying turbines in the turbine cata with .dae data was not possible. {{Templink35SP2|01_2991}}
 
===DECIBEL===
*Fixed issue where copied calculations would sometimes revert to Finnish DL90 Keränen 2018. {{Templink35SP2|06_0368}}
 
===MCP===
*Fixed issue where result-to-file would not be updated after re-calculating a cloned calculation. {{Templink35SP2|03_0203}}
 
===METEO===
*Fixed issue where wiewing the calibration setup with partially defined import setup could cause an exception. {{Templink35SP2|25_0804}}
*Fixed issue with calibration periods not being detected correctly for .row-files {{Templink35SP2|25_0807}}
*Fixed annoyance with repetitive warnings after recalibration changes. {{Templink35SP2|25_0809}}
*Fixed issue with recognizing the correct recalibration periods of Ammonit logger files. {{Templink35SP2|25_0810}}
*Fixed issue where the "Description" data in RWD data would not be not reported in the Device name column under Configuration table. {{Templink35SP2|25_0816}}
 
===SHADOW===
*Fixed issue where the report column "Calculation distance" sometimes would not be printed. {{Templink35SP2|07_0220}}
*Updated sun statistics according to guidelines from the Danish Housing and Planning Authority. {{Templink35SP2|07_0222}}
 
===SITE COMPLIANCE===
*Adjusted default settings for WEng based ambient turbulence. {{Templink35SP2|29_0417}}
 
===SOLAR PV===
*Fixed issue where buffers would not be applied on north and south sides of PV areas. {{Templink35SP2|58_0259}}
*Fixed issue in result-to-file where the gross production of the backside panel would include the front side production. The issue did not influence AEP. {{Templink35SP2|58_0261}}
 
===TR10===
*Fixed a range of minor issues, improving results. {{Templink35SP2|60_0195}}
 


The latest version of windPRO can always be downloaded here: https://www.emd.dk/windpro/downloads/
The latest version of windPRO can always be downloaded here: https://www.emd.dk/windpro/downloads/

Revision as of 10:13, 5 April 2022

Below you will find a list of all issues fixed in Service Pack 2:

This Service Pack contains corrections to bugs and comments reported by users. Thanks to all for submitting feedback.

BASIS

  • Clarified help text in turbine catalogue concerning blade width.
  • Fixed issue where copying turbines in the turbine cata with .dae data was not possible.

DECIBEL

  • Fixed issue where copied calculations would sometimes revert to Finnish DL90 Keränen 2018.

MCP

  • Fixed issue where result-to-file would not be updated after re-calculating a cloned calculation.

METEO

  • Fixed issue where wiewing the calibration setup with partially defined import setup could cause an exception.
  • Fixed issue with calibration periods not being detected correctly for .row-files
  • Fixed annoyance with repetitive warnings after recalibration changes.
  • Fixed issue with recognizing the correct recalibration periods of Ammonit logger files.
  • Fixed issue where the "Description" data in RWD data would not be not reported in the Device name column under Configuration table.

SHADOW

  • Fixed issue where the report column "Calculation distance" sometimes would not be printed.
  • Updated sun statistics according to guidelines from the Danish Housing and Planning Authority.

SITE COMPLIANCE

  • Adjusted default settings for WEng based ambient turbulence.

SOLAR PV

  • Fixed issue where buffers would not be applied on north and south sides of PV areas.
  • Fixed issue in result-to-file where the gross production of the backside panel would include the front side production. The issue did not influence AEP.

TR10

  • Fixed a range of minor issues, improving results.