Line 18: | Line 18: | ||
*Fixed issue with calibration periods not being detected correctly for .row-files {{Templink35SP2|25_0807}} | *Fixed issue with calibration periods not being detected correctly for .row-files {{Templink35SP2|25_0807}} | ||
*Fixed issue with recognizing the correct recalibration periods of Ammonit logger files. {{Templink35SP2|25_0810}} | *Fixed issue with recognizing the correct recalibration periods of Ammonit logger files. {{Templink35SP2|25_0810}} | ||
*Fixed issue with Ammonit API | *Fixed issue with Ammonit API {{Templink35SP2|25_0828}} | ||
*Fixed annoyance with repetitive warnings after recalibration changes. {{Templink35SP2|25_0809}} | *Fixed annoyance with repetitive warnings after recalibration changes. {{Templink35SP2|25_0809}} | ||
*"Description" data in RWD data is now reported in the Device name column under Configuration table. {{Templink35SP2|25_0816}} | *"Description" data in RWD data is now reported in the Device name column under Configuration table. {{Templink35SP2|25_0816}} |
Revision as of 11:35, 26 April 2022
Below you will find a list of all issues fixed in Service Pack 2:
This Service Pack contains corrections to bugs and comments reported by users. Thanks to all for submitting feedback.
BASIS
- Clarified help text in turbine catalogue concerning blade width.
- Fixed issue where copying turbines in the turbine cata with .dae data was not possible.
DECIBEL
- Fixed issue where copied calculations would sometimes revert to Finnish DL90 Keränen 2018.
- Fixed issue where missing octave data at hub height would throw an exception instead of offering mitigation options. {{Templink35SP2|}06_0373}
MCP
- Fixed issue where result-to-file would not be updated after re-calculating a cloned calculation.
METEO
- Fixed issue where viewing the calibration setup with partially defined import setup could cause an exception.
- Fixed issue with calibration periods not being detected correctly for .row-files
- Fixed issue with recognizing the correct recalibration periods of Ammonit logger files.
- Fixed issue with Ammonit API
- Fixed annoyance with repetitive warnings after recalibration changes.
- "Description" data in RWD data is now reported in the Device name column under Configuration table.
PARK
- Fixed issue where the presence of e.g. 2 full years of data, separated by an empty year would not allow PARK to run.
SHADOW
- Fixed issue where the report column "Calculation distance" sometimes would not be printed.
- Updated sun statistics according to guidelines from the Danish Housing and Planning Authority.
SITE COMPLIANCE
- Fixed issue where Ambient turbulence would not show up in the Detaild graphic results of Effective Turbulence calculation
- Adjusted default settings for WEng based ambient turbulence.
- Fixed error in ed.4 where the check interval for wind speeds were defined as for ed. 3 instead of for ed.4. This might influence the "Warning" / "Critical" transition
- Fixed issue where Ambient turbulence would not show up in the Detaild graphic results of Effective Turbulence calculation
SOLAR PV
- Fixed issue where buffers would not be applied on north and south sides of PV areas.
- Fixed issue in result-to-file where the gross production of the backside panel would include the front side production. The issue did not influence AEP.
TR10
- Fixed a range of minor issues, improving results.
ZVI
- Fixed issue where printing a cumulative impact report after calculating subtended angles could sometimes cause an exception.
The latest version of windPRO can always be downloaded here: https://www.emd.dk/windpro/downloads/