Difference between revisions of "Writing multiple timeseries to meteo object from MCP2005"

From Wiki-WindPRO
Jump to navigation Jump to search
 
Line 3: Line 3:
 
[[Category:windPRO Known Issues]]
 
[[Category:windPRO Known Issues]]
  
'''Status:''' Open - will be fixed in windPRO 3.2 Service Pack 1
+
'''Status:''' Fixed in windPRO 3.2 Service Pack 1
  
 
'''Fixed in build:''' 670
 
'''Fixed in build:''' 670

Latest revision as of 13:05, 19 June 2018


Status: Fixed in windPRO 3.2 Service Pack 1

Fixed in build: 670

Writing multiple time series to meteo objects from the same MCP2005-calculation can cause data loss if you subsequently open and close the meteo objects. Example:

1) Two meteo objects have been created from MCP2005, A & B

2) If you exit MCP2005, open and close Meteo Object A the data is saved/updated as expected.

3) Due to an error, opening and closing Meteo Object B will replace the time series data of Meteo Object A.

Note that this error does not apply to the new edition of MCP.

Workaround: Before closing the generated meteo objects with "OK" ensure that the "Object data placement" has been set to "Internal" in the Meteo Object Setup found on the Data-tab.